Error Messages - Emerson DL8000 Instruction Manual

Preset controller
Hide thumbs Also See for DL8000:
Table of Contents

Advertisement

DL8000 Preset Instruction Manual
E.5.8 Error Messages
E-100
 14/03/12 12:26:02
Set Port
Rx Bytes / Tx Bytes
Baud rates
Par/StopBit/DataBit
Diag. in progress...
Please Wait...
The system also tests parity bits, stop bits, and data bits, again using P
to indicate a successful test and F to indicate a failure. When the test
completes the message STOP to End appears at the bottom of the
screen:
 14/03/12 12:26:02
Set Port
Rx Bytes / Tx Bytes
Baud rates
Par/StopBit/DataBit
(STOP to End )
Press STOP to end the test and return to the comm port selection
screen. Press EXIT to display the Diagnostics main menu.
Table E-11 lists error messages that could appear on the DL8000
display.
Message
Archive Config Err
Blend Toler. Fail
Btch/Trans Lmt Cros
Invd Additive
Inv Adtv type
Invd Comp Ratio
Invd Delivery Seq
Invd Meter
Invd Driver
Invd Prset Adtv op
DL8000 Keypad Display
RS485 ch 4
120/120
PPPPPPPPP
RS485 ch 4
120/120
PPPPPPPPP
PPP
Table E-11. Error Messages
Description
Transaction or batch configuration error
Preset verification failed; component percentages
are out of allowed tolerance limit
Preset verification failed; limit on batches per
transaction exceeded.
Additive verification failed
Recipe verification failed; invalid additive type
Recipe verification failed; invalid component ratio
in selected recipe
Recipe verification failed; invalid delivery
sequence
Recipe verification failed; invalid meter
assignment
Invalid driver ID entered
Recipe verification failed; invalid additive preset
option
Revised February-2016