Revised February-2016
Table E-3 lists the possible status messages that could display on the
Loading screen during various stages during the load:
Table E-3. Loading Screen Status Messages
Message
Start to Load
Line Pack delay
Load in Progress
Shutting Valve
Pump Stop Delay
Batch Halt
Alarm Halt
Transaction Ended
Batch Aborted
Batch Ended
Batch Complete
Opening BV
Archiving Batch
Archiving Transac
Printing Ticket
CRC Fail, Wait
Prebatch Testing
According to Industry Canada standard requirements, the display
test executes before actual loading starts. This test switches on and
off every pixel of the display (Left and Right screen). The separating
line between displays remains as it.
The display test executes only when the parameter "Display test on
batch start" [TLP 62,0,185] is Enabled (set to 1)
If enabled, the test executes in both manual and auto modes.
DL8000 Keypad Display
DL8000 Preset Instruction Manual
Description
Press Start key to start loading
Indicates the pump for the component is running
and loading line is being packed.
Indicates the batch delivery is in progress in a
normal manner.
Indicates that all open flow control valves are
closing
Waiting for pump to close; flow control valve is
already closed
Indicates current batch is halted
Indicates current batch halted due to alarm
Indicates transaction has ended
Indicates batch has aborted
Indicates batch has ended
Indicated batch has completed after batch
archiving
Indicates the block valve for the component is
being opened
Indicates batch data is being archived
Indicates that transaction data archiving is
occurring
Indicates the ticket is being printed
Indicates the integrity check for user program
images has failed
Indicates the integrity check for user programs is
running
E-9