Transaction Data By Component (0X1F) - Emerson DL8000 Instruction Manual

Preset controller
Hide thumbs Also See for DL8000:
Table of Contents

Advertisement

DL8000 Preset Instruction Manual
Request Transaction
Storage Status
[0x1E]
Transaction Data by
Component
D-54
Deviations
Requests data for the transaction after the current transaction has ended. The
DL8000 sets a flag indicating that the transaction has ended. In manual
operating mode, press Stop to end a transaction when there is a transaction
[0x1F]
in progress and no batch in progress. In automatic operating mode, you end a
transaction using the End Transaction command [0x07].
Flags Immediately Set
Flags Immediately
Exceptions
Supporting
Parameters
Communications Protocols
Results
The command response frame consists of the
following parameter values:
Oldest Transaction sequence number stored
[61,0,123]
Number of Transactions stored [61,0,122]
Maximum number of transactions that can be
stored [61,0,121]
Transaction Configuration Error [61,0,133]
Oldest Batch sequence number stored
[61,0,129]
Number of Batches stored [61,0,128]
Maximum number of batch that can be stored
[61,0,127]
Batch Configuration Error [61,0,134]
None
None
None
Cleared
No Transaction ended
Invalid transaction sequence number
Preset delivery type [63,0,29]
Revised February-2016