DL8000 Preset Instruction Manual
D.8

Status Flags Description [63,0,119]

Status Flag
Additive Selected
Batch Aborted (not started)
Batch Authorized
D-80
The following table describes activities that set or reset status flags.
Table D-4. Status Flag Descriptions
Flag sets when...
Operator selects additive through
keypad.
Note: If TAS writes additive
selection to [63,0,60] then
flag does not change.
Operator presses Stop key for
authorized batch after entering
preset volume (in manual
mode).
Operator issues Stop Batch
command for authorized batch
which is not in progress (in auto
mode).
TAS issues End Batch
command for authorized batch
which is not in progress (in auto
mode).
DL8000 powers up for a
previously authorized batch
which was not in progress when
DL8000 powered down.
Note: If authorized batch was
running, flag resets.
Batch number reduces
by one.
Batch authorizes (in manual
mode).
Authorize Batch command
received (in auto mode).
Communications Protocols
Flag resets when...
Transaction authorizes (in
manual mode)
Authorize Transaction
command received (in auto
mode)
Prompt Additive command
received.
Additive selection screen is
prompted (in manual mode).
Operating mode changes.
DL8000 powers on.
Clear Status command received
(in auto mode with bit 05h).
Clear Status command received
(in auto mode with 0Eh bit).
Authorize Batch command
received (in auto mode).
Batch authorizes (in manual
mode).
Operating mode changes.
Batch ends (sets 0Dh).
Batch aborts.
DL8000 powers up.
Revised February-2016