LED S
L
POT
IGHT
The LED Spot light consists of two LED lamps located on either side of the nozzle. These LED lights are controlled
by a 12 VDC output from the Valve Control Board.

Replacing the LED Spot Light Assembly

If it is determined that the LED Spot Light Assembly is not functioning properly, replace it by performing the proce-
dure below.
1. Shut down the unit using the service menu on the display.
2. Unplug the power cord from the wall receptacle.
3. Open the door.
4. Remove the LED spot lights from their mounts.
5. Unplug the LED spot light assembly connector from
the Valve Control board and free it from the wire
loom.
6. Pull the two LED assemblies and remove them from
the unit.
7. Replace the LED spot light assembly with a new
unit.
8. Route the connector back up to the Valve Control board and plug it in.
9. Reconnect the power cord in the wall receptacle and resume normal operation.
© 2015-2016, Cornelius Inc.
A
SSEMBLY
PBD175 (Spire 3.0) Service Manual
Down
LED
Connector
- 35 -
LED Down
Lights
Figure 61.
Figure 62.
Publication Number: 620062609SER