Off-Cycle Agitator Settings; Ice Chute Restrictor Adjustment - Cornelius pbd175 Service Manual

Cornelius pbd175 dispenser
Table of Contents

Advertisement

PBD175 (Spire 3.0) Service Manual
O
-C
A
FF
YCLE
GITATOR
It is important to correctly set the ON/OFF times for off-cycle ice agitation to prevent ice dispense and storage issues.
The default factory timer settings are set at 4 seconds ON / 1 hour OFF. It may be necessary to adjust these times
based on ice type and quality used with this dispenser.
I
C
R
CE
HUTE
ESTRICTOR
To adjust ice flow rate out of the ice chute, it may be necessary to increase or decrease flow rate based on customer
use and/or ice type. The default factory ice opening is 1.5".
Softer ice types should require the restrictor to be opened completely to prevent ice storage or 'balling' issues.
It may be necessary to order a soft ice slide kit for use of soft/chunklet ice. Contact your local Cornelius Sales Repre-
sentative or Customer Service for more details.
A. Remove ice chute cover
B. Loosen the 4 nuts
C. Push restrictor plate up for more flow, down for less flow
D. Tighten and torque nuts in a crisscross pattern to the specified torque value.
• ED models – torque to approx. 12 in/Lbs
• IDC models – torque to approx. 32 in/Lbs
!
IMPORTANT:
Failure to torque nuts properly may result in a poor gasket seal/ water leakage. Be sure to torque nuts properly.
Publication Number: 620062609SER
S
ETTINGS
Figure 89.
A
DJUSTMENT
Figure 90.
- 44 -
© 2015-2016, Cornelius Inc.

Hide quick links: