Table Ic 124 (Basic Storage Controls) - SMA SUNNY TRIPOWER 60 Technical Information

Sunspec modbus interface
Hide thumbs Also See for SUNNY TRIPOWER 60:
Table of Contents

Advertisement

STP60 SunSpec Modbus Profile – Assignment Tables
Control of the percentile reactive power limitation (VArPct_Ena),
40366
(SMA: Qext): 1 = activated
40367 Scale factor power specification value (WMaxLimPct_SF): -2
40368 Scale factor power factor (OutPFSet_SF): -4
40369 Scale factor reactive power (VArPct_SF): -2
5.2.9

Table IC 124 (Basic Storage Controls)

Description / Number code
Header:
Model ID (ID):
40370
124 = SunSpec Storage Model
Number of the following Modbus registers in accordance with
40371
the PICS table (L): 24
IC 124 block was included for reasons of compatibility and only contains NaN values in the
registers 40372 to 40395
5.2.10 Table IC 126 (Static Volt-VAR Arrays)
Description / Number code
Header:
Model ID (ID):
40396
126 = SunSpec Static Volt-VAR Model
Number of the following Modbus registers in accordance with
40397
the PICS table (L): 64
IC 126 block was included for reasons of compatibility and only contains NaN values in the
registers 40398 to 40461
32
STP60-SunSpec_Modbus-TI-en-12
SMA Solar Technology AG
1
enum16
RW
1
sunssf
RO
1
sunssf
RO
1
sunssf
RO
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
uint16
RO
Technical Information

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents