Table Ic 122 (Inverter Controls Extended Measurements) - SMA SUNNY TRIPOWER 60 Technical Information

Sunspec modbus interface
Hide thumbs Also See for SUNNY TRIPOWER 60:
Table of Contents

Advertisement

STP60 SunSpec Modbus Profile – Assignment Tables
5.2.7

Table IC 122 (Inverter Controls Extended Measurements)

Description / Number code
Header:
Model ID (ID):
40298
122 = SunSpec Measurements Status Model
Number of the following Modbus registers in accordance with
the PICS table (L):
40299
44
Fixed block:
PV inverter availability status (PVConn): NaN
Bit 0 = Connected
40300
Bit 1 = Available
Bit 2 = In operation
Battery inverter availability status (StorConn): NaN
Bit 0 = Connected
40301
Bit 1 = Available
Bit 2 = In operation
ECP connection status (ECPConn): NaN
40302
Bit 0 = Connected
40303 Total active power yield (ActWh), in Wh: NaN
40307 Total apparent power yield (ActVAh), in VAh: NaN
40311 Total reactive power yield in Q 1 (ActVArhQ1), in varh: NaN
40315 Total reactive power yield in Q 2 (ActVArhQ2), in varh: NaN
40319 Total reactive power yield in Q 3 (ActVArhQ3), in varh: NaN
40323 Total reactive power yield in Q 4 (ActVArhQ4), in varh: NaN
Reactive power available independently of active power
40327
(VArAval), in var
Scale factor independently available reactive power (VArA-
40328
val_SF): NaN
28
STP60-SunSpec_Modbus-TI-en-12
VArAval_SF
(40328): NaN
SMA Solar Technology AG
1
uint16
RO
1
uint16
RO
1
bitfield16 RO
1
bitfield16 RO
1
bitfield16 RO
4
acc64
RO
4
acc64
RO
4
acc64
RO
4
acc64
RO
4
acc64
RO
4
acc64
RO
1
int16
RO
1
sunssf
RO
Technical Information

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents