SMA SUNNY TRIPOWER 60 Technical Information page 29

Sunspec modbus interface
Hide thumbs Also See for SUNNY TRIPOWER 60:
Table of Contents

Advertisement

SMA Solar Technology AG
Available reactive power (WAval), in var
40329
NaN
40330 Scale factor available reactive power (WAval_SF): NaN
Indicators for thresholds reached (StSetLimMsk): NaN
0 = WMax
1 = VAMax
2 = VArAval
3 = VArMaxQ1
4 = VArMaxQ2
40331
5 = VArMaxQ3
6 = VArMaxQ4
7 = PFMinQ1
8 = PFMinQ2
9 = PFMinQ3
10 = PFMinQ4
Indicators for currently active inverter controls (StActCtl): NaN
0 = FixedW
1 = FixedVAR
2 = FixedPF
3 = Volt VAr
4 = Freq watt param
5 = Freq watt curve
40333
6 = Dyn reactive current
7 = LVRT
8 = HVRT
9 = Watt PF
10 = Volt watt
12 = Scheduled
13 = LFRT
14 = HFRT
40335 Used time synchronization source (TmSrc), as a URL: NaN
40339 Seconds since 2000-01-01 00:00 UTC (Tms), in s. NaN
Technical Information
STP60 SunSpec Modbus Profile – Assignment Tables
WrAval_SF
(40330):
STP60-SunSpec_Modbus-TI-en-12
1
uint16
RO
1
sunssf
RO
2
bitfield32 RO
2
bitfield32 RO
4
string
RO
2
uint32
RO
29