Table Ic 121 (Inverter Controls Basic Settings) - SMA SUNNY TRIPOWER 60 Technical Information

Sunspec modbus interface
Hide thumbs Also See for SUNNY TRIPOWER 60:
Table of Contents

Advertisement

SMA Solar Technology AG
5.2.6

Table IC 121 (Inverter Controls Basic Settings)

Description / Number code
Header:
Model ID (ID):
40266
121 = SunSpec Basic Settings Model
Number of the following Modbus registers in accordance with
40267
the PICS table (L): 30
Fixed block:
Setting for maximum output active power (WMax),
40268
WMax_SF
in W
Voltage at the PCC (VRef), in V
40269
OM_LL).
Offset between PCC and inverter (VRefOfs), in V
40270
(40290), (SMA: UNOMOFFSET).
Set value for maximum voltage (VMax), in V
40271
(40291): NaN
Set value for minimum voltage (VMin), in V
40272
NaN
Set value for maximum apparent power (VAMax),
40273
VAMax_SF
in VA
Maximum reactive power in Q 1 (VArMaxQ1), in var
40274
(40293) : NaN
Maximum reactive power in Q 2 (VArMaxQ2), in var
40275
(40293) : NaN
Maximum reactive power in Q 3 (VArMaxQ3), in var
40276
(40293) : NaN
Maximum reactive power in Q 4 (VArMaxQ4), in var
40277
(40293) : NaN
Technical Information
(40288), (SMA: SGridNom*P_LIM_IF_Q).
VRef_SF
(40292): NaN
STP60 SunSpec Modbus Profile – Assignment Tables
(40289), (SMA: UN-
VRefOfs_SF
VMinMax_SF
VMinMax_SF
(40291):
VArMax_SF
VArMax_SF
VArMax_SF
VArMax_SF
STP60-SunSpec_Modbus-TI-en-12
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
uint16
RW
1
int16
RW
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
int16
RO
1
int16
RO
1
int16
RO
1
int16
RO
25