STP60 SunSpec Modbus Profile – Assignment Tables
Standard active power increase rate (WGra), in % of
40278
(WMax/min)
Set value for minimum power factor in Q 1 (PFMinQ1)
40279
(40295) : NaN
Set value for minimum power factor in Q 2 (PFMinQ2)
40280
(40295) : NaN
Set value for minimum power factor in Q 3 (PFMinQ3)
40281
(40295) : NaN
Set value for minimum power factor in Q 4 (PFMinQ4)
40282
(40295) : NaN
VAr action when changing between charging and discharging
(VArAct): NaN
40283
1 = Change excitation type
2 = Do not change excitation type
Calculation method for total apparent power (ClcTotVA): NaN
40284
1 = vectorial
2 = arithmetic
Relative maximum increase rate (MaxRmpRte), in % of
40285
MaxRmpRte_SF
WGra
Set value for nominal frequency (ECPNomHz), in Hz
40286
(40297): NaN
Identity of the line conductor in single-phase inverters (ConnPh):
NaN
1 = Line conductor L1
40287
2 = Line conductor L2
3 = Line conductor L3
40288 Scale factor for output active power (WMax_SF): 3
40289 Scale factor reference voltage (VRef_SF): 2
40290 Scale factor for offset (VRefOfs_SF): 2
Scale factor maximum and minimum voltage (VMinMax_SF):
40291
NaN
40292 Scale factor apparent power (VAMax_SF): NaN
26
STP60-SunSpec_Modbus-TI-en-12
WGra_SF
(40294) : NaN
(40296): NaN
SMA Solar Technology AG
1
uint16
PFMin_SF
1
PFMin_SF
1
PFMin_SF
1
PFMin_SF
1
1
enum16
1
enum16
1
uint16
ECPNomHz_SF
1
uint16
1
enum16
1
sunssf
1
sunssf
1
sunssf
1
sunssf
1
sunssf
Technical Information
RO
int16
RO
int16
RO
int16
RO
int16
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO
RO

Hide quick links: