Sunny Tripower 60 (Unit Id = 126 To 168) - SMA SUNNY TRIPOWER 60 Technical Information

Sunspec modbus interface
Hide thumbs Also See for SUNNY TRIPOWER 60:
Table of Contents

Advertisement

STP60 SunSpec Modbus Profile – Assignment Tables
5.3

SUNNY TRIPOWER 60 (Unit ID = 126 to 168)

You will find a summary of the SunSpec Modbus registers supported by the STP60 as well as a
brief description of the register data in the Technical Information "SunSpec Modbus Interface" at
www.SMA-Solar.com.
5.3.1
Table C 001 (Common Model)
Description/Number Code(s)
Header:
40001 SunSpec ID (SID): 0x53756e53 = SunSpec Modbus Map
40003 Model ID (ID): 1 = SunSpec common model
Number of the following Modbus registers in accordance with
40004
the PICS table (L): 66
Fixed block:
40005 Manufacturer (Mn): "SMA"
40021 Model (Md): "SUNNY TRIPOWER 60"
40037 Options (Opt): "Inverter name"
40045 Version (Vr): Version number of the installed firmware.
Serial number (SN) of the device that uses the Modbus unit ID
40053
stored in the following register.
Modbus unit ID of the device (DA):
40069
126 to 167, corresponding to STP60 1 to 42
40070 Padding register
38
STP60-SunSpec_Modbus-TI-en-12
SMA Solar Technology AG
2
uint32
RO
1
uint16
RO
1
uint16
RO
16
string
RO
16
string
RO
8
string
RO
8
string
RO
16
string
RO
1
uint16
RO
1
pad
RO
Technical Information