Tables I 101, 102, 103 (Inverter Integer Map) - SMA SUNNY TRIPOWER 60 Technical Information

Sunspec modbus interface
Hide thumbs Also See for SUNNY TRIPOWER 60:
Table of Contents

Advertisement

STP60 SunSpec Modbus Profile – Assignment Tables
5.2.4

Tables I 101, 102, 103 (Inverter Integer Map)

Accumulation of the values
The Inverter Manager can be considered as a virtual inverter that combines the individual
measured values of the inverters, where useful.
Description / Number code
Header:
Model ID (ID):
40186
103 = SunSpec Inverter Model (phsABC)
Number of the following Modbus registers in accordance
with the PICS table (L):
40187
50
Fixed block:
40188 AC current (A), in A
Current, line conductor L1 (AphA), in A
40189
all inverters
Current, line conductor L2 (AphB), in A
40190
all inverters
Current, line conductor L3 (AphC), in A
40191
all inverters
40192 Scale factor current (A_SF): -1
Voltage, line conductor L1 to L2 (PPVphAB), in V
40193
: average value of all inverters
Voltage, line conductor L2 to L3 (PPVphBC), in V
40194
: average value of all inverters
Voltage, line conductor L3 to L1 (PPVphCA), in V
40195
: average value of all inverters
Voltage, line conductor L1 to N (PPVphA), in V
40196
average value of all inverters
20
STP60-SunSpec_Modbus-TI-en-12
A_SF
(40192): sum of all inverters
A_SF
A_SF
A_SF
(40192) : sum of
(40192) : sum of
(40192) : sum of
V_SF
(40199)
V_SF
(40199)
V_SF
(40199)
V_SF
(40199) :
SMA Solar Technology AG
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
sunssf
RO
1
uint16
RO
1
uint16
RO
1
uint16
RO
1
uint16
RO
Technical Information