Technical Data; Modbus Communication Ports; Data Processing And Time Behavior - SMA SUNNY TRIPOWER 60 Technical Information

Sunspec modbus interface
Hide thumbs Also See for SUNNY TRIPOWER 60:
Table of Contents

Advertisement

Technical Data

7 Technical Data
7.1

Modbus Communication Ports

The following table shows the default setting of the supported network protocol:
Network protocol
TCP
Communication port not able to be changed
The communication port used for Modbus TCP - 502 - can not be changed.
7.2

Data Processing and Time Behavior

In this section, you will find typical data processing and reaction times of the Modbus interface.
Minimum read-write frequency
The minimum frequency with which data can be requested via the Modbus protocol from the In-
verter Manager or written to the Inverter Manager is 1 Hz. This means that at most one Modbus
command per second is permitted (for supported Modbus commands, see Section 3.5 "Reading
and Writing of Data", page 12).
50
STP60-SunSpec_Modbus-TI-en-12
Communication port
502
SMA Solar Technology AG
Technical Information