Error Responses; Using The Command And Response Table - Extron electronics DSC HD-HD 4K Plus A Series User Manual

Hdmi to hdmi 4k scalers
Hide thumbs Also See for DSC HD-HD 4K Plus A Series:
Table of Contents

Advertisement

Error Responses

When the DSC receives a valid command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command because the
command contains invalid parameters, it returns an error response to the host.
— Invalid input number
E01
— Invalid command
E10
— Invalid preset number
E11
— Invalid port number
E12
— Invalid parameter
E13
— Invalid command for this configuration
E14
— Invalid command for signal type
E17
— Busy
E22
— Privilege violation
E24
— Bad file name or file not found
E28
— Bad file type or size
E33

Using the Command and Response Table

The
Command and Response Table for SIS
the commands that the DSC scaler recognizes as valid, the responses that are returned to
the host, a description of the command function or the results of executing the command,
and some examples of the command syntax in ASCII.
NOTE: Unless otherwise stated, upper- and lowercase text can be used
interchangeably in the commands.
ASCII to HEX Conversion Table
Space
Figure 32.
ASCII to Hexadecimal Character Conversion Table
DSC HD-HD 4K Plus A Series • Remote Configuration and Control
Commands, beginning on page 52, lists
44