Download Print this page

Error Responses - Extron electronics SENTOSAxi User Manual

Line quadrupler, line doubler

Advertisement

im Vertrieb von
Time-out
Pauses 10 seconds or longer between command sequence ASCII
characters will result in a Time-out. The command operation is
aborted with no other indication that a Time-out has occurred.

Error Responses

When a command is received from the Host, if the Sentosaxi/
Lanciaxi detects an error, it will return an error response. Possible
error responses with a brief description follow:
E01
E06
E10
E13
Sentosaxi xi xi xi xi/Lanciaxi xi xi xi xi-Initiated Messages
When a local event takes place, such as a front panel operation or
an error condition, the Sentosaxi/Lanciaxi responds by sending a
message to the Host. No response from the Host is expected.
These Sentosaxi/Lanciaxi-initiated messages are listed below
(underlined to identify actual message).
(C) Copyright 1998, Extron Electronics (Model), V x.xx
This message is initiated by the Sentosa xi /Lancia xi when it is first
powered on. (Model = Sentosa xi or Lancia xi ), (x.xx is the software
version number)
Reconfig
RS-232 - Overrun
RS-232 - Noise
RS-232 - Framing
RS-232 - Overflow
RAM Test Failed
ROM Checksum Failed
Serial EEPROM Checksum Failed
6811 EEPROM Checksum Failed
New 6811 Installed
New Serial EEPROM Installed
Invalid Jumpers - Unknown - xxxx
Factory Defaults Reset on Channel #1
Factory Defaults Reset on Channel #2
www.camboard.de
Page 3-3
CAMBOARD Electronics
Invalid input channel number (out of range)
Auto-switch mode active (rear panel DIP switch #1 =enable)
Invalid command (Command received is invalid)
Invalid value (out of range)
This message is initiated by the Sentosa xi /Lancia xi
when there is a change in the selected input or any
picture control setting.
These Sentosa xi /Lancia xi -initiated messages
indicate an RS-232 communication error.
Possible causes are RS-232 connection
problem, Baud rate, etc.
Tel. 07131 911201
ce-info@camboard.de
Extron • SENTOSA xi LQ & LANCIA xi LD • User's Manual
Fax 07131 911203
RS-232/REMOTE Control
Call Extron Technical Support if
any of these Sentosa xi /Lancia xi -
initiated messages are reported.
Call Extron Technical Support.
Reported if Freeze button is
depressed during power-up.