Real-Time Clock Register Test; Real-Time Clock Register Test Error Messages; Real-Time Clock Register Test Error Codes And Descriptions - DEC DECstation 5000 Model 200 Maintenance Manual

Hide thumbs Also See for DECstation 5000 Model 200:
Table of Contents

Advertisement

Real-Time Clock Register Test

The real-time clock register test checks the real-time clock
(RTC) registers. To run the real-time clock register test, type
t 7/rtc/regs and press Return.

Real-time clock register test error messages

Real-time clock register test error messages have the form
?TFL: 7/rtc/regs (code description)
?TFL 7/rtc/regs indicates that the real-time clock register
test reported an error.
code represents a code that identifies the portion of the test
that failed.
description represents additional information that describes
the failure.
Table D-19 describes the additional error codes and descriptions
found in real-time clock register test error messages.
Table D-19. Real-Time Clock Register Test Error Codes and Descriptions
Error Code and Description
1
(2: register =xx, sb yy)
D–30 Test Commands and Messages
Meaning
UIP bit remained set past allotted time.
The test failed to write pattern correctly.
The register value is the actual value in the
named register, followed by what the value
should be.

Advertisement

Table of Contents
loading

Table of Contents