Table D-11. Serial Line Transmit and Receive Test Error Descriptions
Error Description
(TCR= xxxx, sb yyyy)
(tx: CSR=xxxx, sb yyyy)
(no tx intrpt)
(timeout: CSR= xxxx, sb yyyy)
(no rcv intrpt)
(bad data=xxxx, sb yyyy)
Meaning
The value in the transmit control register
(TCR) is incorrect. The TCR value is the
actual value in the TCR register, followed
by what the value should be.
Error occurred during transmission
operation. CSR lists the value in the CSR
register (CSR), followed by the correct
value.
No transmission interrupt occurred.
Timeout occurred while waiting for
transmission. CSR lists the value in the
serial line current status register (CSR),
followed by the correct value.
No receive interrupt occurred.
Received data was incorrect. The bad data
parameter lists the incorrect data, followed
by what the value should be.
Test Commands and Messages D–19