Collision Test; Collision Test Parameters And Error Codes; Collision Test Parameters; Collision Test Error Codes - DEC DECstation 5000 Model 200 Maintenance Manual

Hide thumbs Also See for DECstation 5000 Model 200:
Table of Contents

Advertisement

Collision Test

The collision test checks the Ethernet's collision detect circuitry
by forcing a collision on transmit. To run the collision test, type
t x05 P1 and press Return. When you use this test command,
Replace x with the unit number of the Ethernet controller
that you want to test.
Replace the optional P1 parameter with the Ethernet
address in which you want to set up structures.

Collision test parameters and error codes

Table F-41 describes the parameters used in collision test
commands and error messages.
Table F-42 lists the error codes used in collision test error
messages.
Table F-41. Collision Test Parameters
Parameter
Description
P1
Ethernet address used for setting up structures
P2
Return status from any of the common subroutines
P3
Last value read from CSR0
Table F-42. Collision Test Error Codes
Error Code
Description
1
Error occurred reading Ethernet station address ROM.
2
Error occurred transmitting packet.
3
Packet went normally when it should have failed.
4
Error other than retry error occurred during packet
transmission.
Test Commands and Messages Produced by Version PDE3 ROM Chips F–33

Advertisement

Table of Contents
loading

Table of Contents