Line frequency
Valid range, low limit
Valid range, high limit
Power loss
Power loss, typ.
Address area
Address space per module
Address space per module, max.
Hardware configuration
Automatic code
Time
Operating hours counters
Available
Analog inputs
Cycle time (all channels), typ.
Interrupts/diagnostics/status information
Interrupts
Diagnostic alarm
Limit interrupt
Hardware interrupt
Diagnostic indicator LED
Monitoring of supply voltage (PWR LED)
Channel status display
For channel diagnostics
For module diagnostics
Integrated functions
Measuring functions
Buffering of measured variables
Parameter length
Measuring method for voltage measurement
Measuring method for current measurement
Type of measured data acquisition
Voltage wave form
Band width of the measured value detection
Operating mode for measured value acquisition
Analog input module AI Energy Meter 480VAC ST (6ES7134-6PA20-0BD0)
Manual, 12/2015, A5E36061895-AA
Mechanical coding element
Automatic line frequency acquisition
Fixing at 50 Hz
Fixing at 60 Hz
Technical specifications
14.1 Technical specifications
6ES7134-6PA20-0BD0
47 Hz
63 Hz
0.6 W
256 bytes; for input and output data each
Yes
Yes
50 ms. Time for the consistent updating of all
measured and calculated values (cyclic and acy-
clic data)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
74 bytes
TRMS
TRMS
Complete
Sinusoidal or distorted
2 kHz. Harmonic: 39 / 50 Hz, 32 / 60 Hz
No; can be assigned
No; default setting