4. How to Program
This parameter cannot be adjusted while the motor is running.
4
50
1-25 Motor Nominal Speed
Range:
Size re-
[100 - 60,000 rpm]
*
lated
5-12 Terminal 27 Digital Input
Option:
MG.33.A9.22 - VLT is a registered Danfoss trademark
VLT
Function:
Enter the nominal motor speed value from the motor nameplate
data. This data is used for calculating automatic motor com-
pensations.
Function:
Select the function from the available digital input range.
No operation
Reset
Coast inverse
Coast and reset inverse
Quick stop inverse
DC brake inverse
Stop inverse
Start
Latched start
Reversing
Start reverse
Enable start forward
Enable start reverse
Jog
Preset ref bit 0
Preset ref bit 1
Preset ref bit 2
Freeze reference
Freeze output
Speed up
Slow
Set-up select bit 0
Set-up select bit 1
Catch up
Slow-down
Pulse input
Ramp bit 0
Ramp bit 1
Line failure inverse
DigiPot Increase
DigiPot Decrease
DigiPot Clear
Reset Counter A
Reset Counter B
®
AutomationDrive FC 300 Instruction
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[8]
[9]
[10]
[11]
[12]
[13]
[14]
[16]
[17]
[18]
[19]
[20]
[21]
[22]
[23]
[24]
[28]
[29]
[32]
[34]
[35]
[36]
[55]
[56]
[57]
[62]
[65]
Manual