Brainchild P41 User Manual page 30

Auto-tune fuzzy / pid profiling controller
Table of Contents

Advertisement

Register
Parameter
Address
Notation
123
124
125
126
127
128
PV
129
SV
MV1
130
MV2
131
132
STAT
133
EROR
134
PFSG
135
TNSG
136
TTSG
30
Parameter
Description
Reserved
Reserved
Reserved
Reserved
Reserved
Process value
Set point value for
control
Output 1
percentage
value (Heating )
Output 2
percentage
value (Cooling )
Mode and
operation status
word
Error Code
Current profile
and segment
runing
Total number of
segments
Total time for
segment runing
Range
Low: -32768 High: 32767
Low: SPLO High: SPHI
Low: 0.00
High: 100.00
Low: 0.00
High: 100.00
Bit 0 = Profile run mode
Bit 1 = Profile hold mode
Bit 2 = Static mode
Bit 3 = Automatic tuning mode
Bit 4 = Manual mode
Bit 5 = Off mode
Bit 6 = Failure mode
Bit 7 = Profile running up
Bit 8 = Profile runing down
Bit 9 = Profile soaking
Bit 10 = Alarm 1 active
Bit 11 = Alarm 2 active
Bit 12 = Alarm 3 active
Bit 13 = Event 1 on
Bit 14 = Event 2 on
Bit 15 = Event 3 on
Low: 0
Low: 1.00
Low: 1
Low: 0
UM0P411A
UM0P411A
Default
Value
High: 40
High: 9.63
High: 64
High: 99.59
Data
type
R
R
*1
*1
R
R
R
R
R