Brainchild P41 User Manual page 24

Auto-tune fuzzy / pid profiling controller
Table of Contents

Advertisement

Register
Parameter
Address
Notation
ALF2
62
A2MD
63
A2HY
64
65
ALF3
ALF3
66
A3MD
67
24
Parameter
Description
Alarm 2 function
Alarm 2 operation
mode
Hysteresis control
for alarm 2
Reserved
Alarm 3 function
(for P41 only)
Alarm 3 operation
mode
(for P41 only)
Range
0
: Process high alarm
1
: Process low alarm
2
: Deviation high alarm
3
: Deviation low alarm
4
: Deviation band
high/low alarm
5
: End of profile alarm
6
: Hold mode alarm
7
: Static mode alarm
0
: Normal alarm action
1
: Latching alarm action
2
: Hold alarm action
3
: Latching & hold
alarm action
High: 50.0 C
Low: 0.1
0
: Process high alarm
1
: Process low alarm
2
: Deviation high alarm
3
: Deviation low alarm
4
: Deviation band
high/low alarm
5
: End of profile alarm
6
: Hold mode alarm
7
: Static mode alarm
0
: Normal alarm action
1
: Latching alarm action
2
: Hold alarm action
3
: Latching & hold
alarm action
UM0P411A
Default
Value
2
0
L
L
0.1 C
L
L
(90.0 F)
(0.2 F)
2
0
Data
type
R/W
R/W
R/W
R/W
R/W