Shifter, Bearing And Seal Servicing; Pinion Bearing - Evinrude E-TEC 200 Service Manual

Hide thumbs Also See for E-TEC 200:
Table of Contents

Advertisement

GEARCASE – STANDARD ROTATION

SHIFTER, BEARING AND SEAL SERVICING

NOTICE
Use
Alignment
P/N 354718, to install and remove press fit pro-
peller shaft bearing housing in L2 and M2 Type
gearcase housings.
Failure to follow this procedure will result in
inability to remove gauging head, forward
thrust bearing and forward bearing housing
from gearcase housing.
Alignment Gauge Puller, P/N 354718
IMPORTANT:
DO NOT force gauging shaft into
alignment hole. Shaft MUST slide easily into hole
of gauging head. If shaft does not slide into hole,
gearcase housing is damaged and must be
replaced.
1. Gauging shaft
300
SHIFTER, BEARING AND
Gauge
Puller,
SEAL SERVICING
Pinion Bearing Removal
Remove pinion bearing retaining screw.
1
354718
1. Pinion bearing retaining screw
2. Water screen pocket
3. Seal
Assemble Pinion Bearing Remover and Installer,
P/N 5005927, in the gearcase as follows:
Use a 7/8 in. wrench to hold the remover in place.
Use a 3/4 in. wrench to turn flange nut clockwise.
Draw the bearing up from the housing.
1
004347
1. Flange nut, P/N 326586
2. Plate, P/N 391260
3. Rod, P/N 326582
4. Remover, P/N 326579
2
3
006892
DRC7416
006893
1
2
3
4
DR3419