EVINRUDE ICON REMOTE CONTROL SYSTEM
ICON SYSTEM SETTINGS
linkage. Evinrude Diagnostics reports when the
process is complete.
2
1. Calibrate Throttle button
2. Process complete message
Shift Actuator Stroke
To set forward gear shift stroke:
•
With the shift link disconnected, rotate the pro-
peller and manually shift the outboard into for-
ward gear with the shift lever.
1. Shift lever in forward
IMPORTANT:
Make sure the gear is fully
engaged and the lever is all the way forward.
206
•
Click the Forward button under Shift Calibration
on the EST Calibration screen. The actuator
arm will move forward.
•
Use the Nudge buttons to move the actuator
1
arm forward or backward until the shift link
aligns with the actuator arm and shift lever pins.
• When the link and pins are exactly aligned,
install the link and click the Save button. The
actuator will move to the neutral position.
1
008133
1. Forward calibration button
2. Nudge buttons
3. Save button
1
008510
To set reverse gear shift stroke:
•
Remove shift link.
2
3
008134
008511