5. Remove the eight screws and three ground-
ing terminals.
6. Remove the AC inlet.
7. Remove the one connector.
8. Remove the PWB connector between con-
nect-L PWB and then remove the power
source unit.
9. Remove the power source unit.
10. Check or replace the power source unit and
refit all the removed parts.
Screw
Grounding
terminal
Grounding
terminal
Screw
Screw
Grounding
Screw
terminal
Connect-L PWB
Connector
AC inlet
Screw
Screw
Screw
Screw
Figure 1-5-41
PWB connector
Power source unit
Figure 1-5-42
2F7-2