2F7
(5) Detaching and refitting the fuser thermistor M, fuser thermistor S and thermal cutout
Procedure
1. Remove the fuser unit (See page P.1-5-15).
2. Turn the fuser unit bottom side up.
3. Unlatch the two latches and then remove
the cord cover.
4. Unlatch the four latches and then remove
the fuser drawer connector.
5. Remove the two connectors.
6. Remove the heat roller (See page P.1-5-18).
7. Remove the one screw and then remove the
fuser thermistor S.
1-5-20
Latch
Latch
Latch
Fuser drawer
Connector
connector
Figure 1-5-26
Fuser
thermistor S
Figure 1-5-27
Cord cover
Latch
Connector
Fuser unit
Screw