Kyocera FS-6950DN Service Manual page 45

Hide thumbs Also See for FS-6950DN:
Table of Contents

Advertisement

Service items
>>Developer
>>DRUM-CTRL
Initializing the developer unit (toner install mode)
Description
The new developer unit is shipped from the factory with no toner contained. The developer
can be automatically replete with toner when a toner container is installed onto it and the
printer is turned on. However, because the toner reservoir in the developer has a large
capacity, it requires a lengthy period of time until a substantial amount of toner has been fed
to get the printer ready. (A new developer needs approximately 260 g for triggering the sen-
sor inside.)
Purpose
To execute when the developer unit has been replaced.
Method
1.
Enter the service mode [>>Developer].
2.
Press the OK key. [>>Developer?] will be displayed.
3.
Press the OK key. [Ready] will be displayed.
4.
Turn off and on the printer. [Self test] [Please wait (Adding toner)] will displayed. The
printer continually engages in this mode for a period of approximately 10 minutes,
after which the printer reverts to the [Ready] state. [Ready] will displayed. Devel-
oper initialization is finished.
Completion
Automatic drum surface refreshing
Description
The drum surface refreshing operation is normally performed when the power is turned on to
the printer or during warm-up when the printer is recovering from the Sleep mode, but even
then only at those times that the temperature/humidity sensor detects the drum surface to be
in a state of dew condensation. By using this mode, it is possible to force the drum surface
refreshing operation to be performed automatically at a predetermined period of time,
regardless of the status detected by the temperature/humidity sensor.
Purpose
To prevent bleeding of the output image when the printer's operating environment is one of
high humidity.
Method
1.
Enter the service mode [>>DRUM-CTRL].
2.
Press the OK key. [>>DRUM-CTRL?] will be displayed.
3.
Press the OK key.
4.
Press the
key or
00
Mode turned OFF (default)
01
Refreshing operation time (short)
02
Refreshing operation time (long)
5.
Press the OK key. The new value is set.
Completion
Description
key and select the desire mode (from 00 to 02)