Functions
2.11 Automatic Reclosure Function 79 (Optional)
2.11.4

Information List

No.
Information
127
79 ON/OFF
2701
>79 ON
2702
>79 OFF
2703
>BLOCK 79
2711
>79 Start
2716
>79 TRIP 3p
2727
>79 RemoteClose
2738
>BLOCK 3pole AR
2739
>BLK 1phase AR
2740
>BLK 2phase AR
2741
>BLK 3phase AR
2742
>BLK 1.AR-cycle
2743
>BLK 2.AR-cycle
2746
>Trip for AR
2752
>Pickup 3ph AR
2781
79 OFF
2782
79 ON
2783
79 is blocked
2784
79 not ready
2787
CB not ready
2788
79 T-CBreadyExp
2796
79 on/off BI
2801
79 in progress
2809
79 T-Start Exp
2810
79 TdeadMax Exp
2818
79 Evolving Flt
2821
79 Td. evol.Flt
2840
79 Tdead 3pTrip
2843
79 Tdead 3pFlt
2844
79 1stCyc. run.
2845
79 2ndCyc. run.
2851
79 Close
2853
79 Close1.Cyc3p
2854
79 Close 2.Cyc
2861
79 T-Recl. run.
2862
79 Successful
2871
79 TRIP 3pole
2889
79 1.CycZoneRel
2890
79 2.CycZoneRel
2894
79 Remote Close
154
Type of In-
formation
IntSP
79 ON/OFF (via system port)
SP
>79 ON
SP
>79 OFF
SP
>BLOCK 79
SP
>79 External start of internal A/R
SP
>79: External 3pole trip for AR start
SP
>79: Remote Close signal
SP
>79: Block 3pole AR-cycle
SP
>79: Block 1phase-fault AR-cycle
SP
>79: Block 2phase-fault AR-cycle
SP
>79: Block 3phase-fault AR-cycle
SP
>79: Block 1st AR-cycle
SP
>79: Block 2nd AR-cycle
SP
>79: External Trip for AR start
SP
>79: External pickup 3phase for AR start
OUT
79: Auto recloser is switched OFF
IntSP
79: Auto recloser is switched ON
OUT
79: Auto recloser is blocked
OUT
79: Auto recloser is not ready
OUT
79: Circuit breaker 1 not ready
OUT
79: CB ready monitoring window expired
IntSP
79: Auto recloser ON/OFF via BI
OUT
79 - in progress
OUT
79: Start-signal monitoring time expired
OUT
79: Maximum dead time expired
OUT
79: Evolving fault recognition
OUT
79 dead time after evolving fault
OUT
79 dead time after 3pole trip running
OUT
79 dead time after 3phase fault running
OUT
79 1st cycle running
OUT
79 2nd cycle running
OUT
79 - Close command
OUT
79: Close command after 3pole, 1st cycle
OUT
79: Close command 2nd cycle (and higher)
OUT
79: Reclaim time is running
OUT
79 - cycle successful
OUT
79: TRIP command 3pole
OUT
79 1st cycle zone extension release
OUT
79 2nd cycle zone extension release
OUT
79 Remote close signal send
Comments