Siemens SIPROTEC 7SD80 Manual page 380

The digital overcurrent protection
Hide thumbs Also See for SIPROTEC 7SD80:
Table of Contents

Advertisement

Appendix
A.9 Information List
No.
Description
2752
>79: External pickup 3phase for
AR start (>Pickup 3ph AR)
2781
79: Auto recloser is switched OFF
(79 OFF)
2782
79: Auto recloser is switched ON
(79 ON)
2783
79: Auto recloser is blocked (79 is
blocked)
2784
79: Auto recloser is not ready (79
not ready)
2787
79: Circuit breaker 1 not ready
(CB not ready)
2788
79: CB ready monitoring window
expired (79 T-CBreadyExp)
2796
79: Auto recloser ON/OFF via BI
(79 on/off BI)
2801
79 - in progress (79 in progress)
2809
79: Start-signal monitoring time
expired (79 T-Start Exp)
2810
79: Maximum dead time expired
(79 TdeadMax Exp)
2818
79: Evolving fault recognition (79
Evolving Flt)
2821
79 dead time after evolving fault
(79 Td. evol.Flt)
2840
79 dead time after 3pole trip
running (79 Tdead 3pTrip)
2843
79 dead time after 3phase fault
running (79 Tdead 3pFlt)
2844
79 1st cycle running (79 1stCyc.
run.)
2845
79 2nd cycle running (79 2ndCyc.
run.)
2851
79 - Close command (79 Close)
2853
79: Close command after 3pole,
1st cycle (79 Close1.Cyc3p)
2854
79: Close command 2nd cycle
(and higher) (79 Close 2.Cyc)
2861
79: Reclaim time is running (79 T-
Recl. run.)
2862
79 - cycle successful (79 Suc-
cessful)
2871
79: TRIP command 3pole (79
TRIP 3pole)
2889
79 1st cycle zone extension
release (79 1.CycZoneRel)
2890
79 2nd cycle zone extension
release (79 2.CycZoneRel)
2894
79 Remote close signal send (79
Remote Close)
2896
No. of 1st AR-cycle CLOSE com-
mands,3pole (79 #Close1./3p=)
2898
No. of higher AR-cycle CLOSE
commands,3p (79 #Close2./3p=)
3102
Tolerance invalid in phase A (2nd
Harmonic A)
380
Function
Type
Log Buffers
of In-
for-
matio
n
79 Auto Recl.
SP
*
ON
79 Auto Recl.
OUT
On
*
Off
79 Auto Recl.
IntSP
*
*
79 Auto Recl.
OUT
On
*
Off
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
*
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
IntSP
*
*
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
On
Off
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
*
79 Auto Recl.
OUT
*
*
79 Auto Recl.
OUT
*
*
79 Auto Recl.
OUT
*
*
79 Auto Recl.
OUT
*
ON
79 Auto Recl.
OUT
*
*
79 Auto Recl.
OUT
*
*
79 Auto Recl.
OUT
*
ON
Statistics
VI
Statistics
VI
InRushRestraint
OUT
*
Configurable in Matrix
*
LED BI
BO
40
*
LED
BO
40
*
LED
BO
192
*
LED
BO
40
*
LED
BO
192
*
LED
BO
40
*
LED
BO
40
*
LED
BO
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
m
LED
BO
192
*
LED
BO
40
*
LED
BO
192
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
40
*
LED
BO
92
SIPROTEC, 7SD80, Manual
E50417-G1140-C474-A1, Release date 09.2011
IEC 60870-5-103
47
2
Yes
81
1
Yes
16
1
Yes
83
1
Yes
130
1
Yes
87
1
Yes
88
2
Yes
101
2
Yes
174
2
Yes
175
2
Yes
118
2
Yes
197
2
Yes
149
2
Yes
154
2
Yes
155
2
Yes
157
2
Yes
128
2
No
153
1
Yes
129
1
No
161
1
Yes
162
1
Yes
171
2
Yes
160
1
Yes
169
1
Yes
129
2
Yes
89
1
Yes