FX3U-20SSC-H positioning
4.6.3

Testing and monitoring operations

With the parameters and table information saved to the FX
the PLC in STOP mode, testing is performed by using TEST MODE in FX Configurator-FP.
Enter TEST MODE by pressing the Test On/Off
After entering TEST MODE, click on the operation Test X-axis
Operation test window.
Next, select the XY-axis table operation from the X-axis/Pattern combination box and click
on the Start button to begin positioning. Note that because the table operation includes a "Jump"
command, the operation will continuously loop from row 0 to row 20.
Fig. 4-46: X-axis operation tes t window
To stop positioning, click on the All axis stop or Stop button.
After stopping the table operation, a variety of other positioning operations can be tested from
the X-axis/Pattern combination box such as 1-speed positioning, 2-speed positioning, and
linear interpolation.
For additional control in TEST MODE, the other tabs at the top of the X-axis Operation test
window can be used according to the following information:
Position start
Positioning opera-
tions can be executed
from this window.
Target address and
operation speed data
is defined here.
FX Positioning Control Systems
Learning to Use the FX Family for Positioning Control
Feed present value
Speed CHG
CHG
The value of the cur-
Two operations for
rent address can be
changing the speed
changed using this
of the motor are avail-
window.
able from this win-
dow.
-20SSC-H module from section 4.6.3 and
3U
button.
button to display the X-axis
OPR
By clicking on the
[REQ. OPR] button,
zero return is exe-
cuted.
463030da.eps
JOG/MPG
JOG operation and
manual pulsar opera-
tion testing can be
performed from this
window.