Learning to Use the FX Family for Positioning Control
Click on the Positioning tab and then set Y000 (pulse output destination) as follows.
Fig. 4-11: "Positioning" window
Setting item
Bias speed [Hz]
Maximum speed [Hz]
Creep speed [Hz]
Zero return speed [Hz]
Acceleration time [ms]
Deceleration time [ms]
Interrupt input for DVIT instruction
Tab. 4-10: Settings for Y000
The "Bias speed" corresponds to the minimum speed.
Can only be set for a FX
4 - 14
Setting value
500
100,000
1000
50,000
100
100
X000
or FX
main unit.
3U
3UC
MELSEC FX PLC positioning