FX2N-10GM and FX2N-20GM positioning
Below are the four positioning parameter windows from VPS. The settings on these windows should
be copied for BOTH the X- and Y- axes before performing positioning.
Open the "Parameter Units" window by selecting Parameters
main menu bar at the top of the screen.
Fig. 4-37: Parameter Units window
Open the Parameter Speed window by selecting Parameters
the menu bar at the top of the screen.
Fig. 4-38: Parameter Speed window
The Max speed is set very low in order for the VPS software to trace the path during operation
through the Monitoring window. In turn, both the JOG speed and interpolation value must be
reduced. (In practice, it is impossible to have the JOG speed set to a value higher than the Max
speed setting.)