Event buzzer and status output

Decide with which event the buzzer and / or the status output is to be acti-
vated (smoke, window / door supervision or fault input 1 – 8).
It is possible to select several simultaneous events:
Main menu > Supervision > Signaling > Events buzzer:
Main menu > Supervision > Signaling > Events status outp:
Factory setting
Setting

Signal duration

Signal duration for the buzzer and the status output can be selected (1 – 60
minutes, "--- " unlimited). When the set signal time has elapsed, the buzzer
stops and the status output's relay drops out again, even if the triggering event
is still pending.
Main menu > Supervision > Signaling > Signal duration:
Factory setting
Your setting
As soon as one of the buttons on the central apartment unit is pressed,
both buzzer and status output will immediately be deactivated again –
independent of the set signal duration.

Holidays / special days

Calendar

Setting holidays / special days

If you are absent for one or several days, or if your occupancy pattern is dif-
ferent on certain days (e.g. on public holidays), you can define a holiday pe-
riod or a special day. For each of the possible 16 entries made, start, end and
the reason (holidays or special day) can be entered.
In that case, you can also define whether the event is repeated every year
(* with entry of year), or whether it should be deleted again after the event
took place (entry with indication of year).
68 / 100
Siemens
Building Technologies
Events buzzer
Smoke
Window/door supervision
Smoke
Window/door supervision
Fault input 1
Fault input 2
Fault input 3
Fault input 4
Fault input 5
Fault input 6
Fault input 7
Fault input 8
3 minutes
Synco™ living Operating instructions
Central apartment unit QAX910
Events status output
Smoke
Window/door supervision
Smoke
Window/door supervision
Fault input 1
Fault input 2
Fault input 3
Fault input 4
Fault input 5
Fault input 6
Fault input 7
Fault input 8
CE1B2707en
23.08.2008