For each fault output, the following settings can be made:
Fault priority: The priority (urgent or Not urgent) with which the relay should be
energized can be selected here
Fault source: Defines whether the relay should respond only in the case of
internal faults or only in the case of external faults (faults transmitted via bus)
Maximum one bus fault status message can be handled. If both relays
are set as bus relays with different priorities, only one of them can be
energized at a time, even if several faults with different priorities are
pending on the bus! It is therefore recommended to configure only one
relay as a bus fault relay.
Fault relay
FS fault priority
Fault priority
FS fault source
Fault source
FS
Factory setting
The fault relay remains energized until the fault is acknowledged.
Texts

Plant name

Assign the plant or the apartment a self-explanatory name,
e.g. "Main street 22":
Main menu > Settings > Text > Plant name:
Room names 1 – 12
Assign the rooms self-explanatory names, e.g. Living, Eating, Parents, Chil-
dren, Bathroom, etc.:
Main menu > Settings > Text > Rooms > Room X:
Switching group names 1 – 8
Assign the switching groups self-explanatory names, e.g. Living, Eating, Par-
ents, Children, Bathroom, etc.
Main menu > Settings > Text > Switching groups > Switching group X:
78 / 100
Siemens
Building Technologies
1
All
Urgent
Not urgent
All
Internal
Internal
Bus
Synco™ living Operating instructions
Central apartment unit QAX910
2
All
Urgent
Not urgent
All
Bus
Internal
Bus
CE1B2707en
23.08.2008