Multiport Backup - Paradyne COMSPHERE 3920PLUS Installation And Operation Manual

Comsphere 392 plus series;
Hide thumbs Also See for COMSPHERE 3920PLUS:
Table of Contents

Advertisement

COMSPHERE 392xPlus Modems
The CCITT standard for V.34 modulation includes dial- or leased-line operation. For proper
leased-line operation, one modem must be designated as the answer modem while the other
modem must be designated as the originate modem.
The V.34 standard also includes asymmetric rates, automatic adjustment of the transmit power
level, and automatic adjustment of the symbol (baud) rate for optimal data throughput. These
automatic adjustments are made during the training, or modem synchronization, phase via special
line-probing techniques that establish the top-most viable rate of operation. Due to these
techniques, true fixed-rate operation of the modems using V.34 modulation is not possible, since
the line condition may not be capable of supporting the selected rate. Thus, using CT111 and
CT112 for rate control of extended data circuits cannot be used.
When operating in V.34 modulation, you can use the top line of the Quick Configuration screen to
view the current modem transmit rate, the symbol or baud rate, and the transmit level. The
392xPlus modems offer separate options for leased and dial lines to override the asymmetric rate
function, since this can cause problems for certain DTE equipment, Also, each symbol rate
supports a subset of data rates, which make up the whole of the V.34 standard.
When using the V.34 modulation on leased lines with a 2-wire leased backup facility, the backup
line check feature, which tests the backup leased lines for connectivity, cannot be used.

Multiport Backup

When the 392xPlus multiport modem has the MUX mode configuration option set to either
TDM/MSD or Digital Bridge, it is in Multiport mode, and either dial lines or a 2-wire leased line
can be used to back up the primary 4-wire leased line. Backup can be performed automatically
upon loss of the primary leased line, and automatic dial standby also can be used to automatically
return the modems to the primary leased line when restored.
When you use backup functions while in Multiport mode, the modem's automode feature is forced
to Disable. This ensures that the mux is not accidentally disabled by answering a call, which is
using modulation where Multiport mode is not supported. It is important that both modems
participating in the backup are in Multiport mode with the same dial-line modulation.
1-10
Symbol Rate
3429
3200
3000
2800
2743
2400
When a 2400 V.34 modulation connection occurs on one end of a
modem pair with configuration options set for Asymmetric rates, the
other modem is 24K due to the 2400 symbol rate it uses.
November 1996
Supported Data Rates
4800 – 33.6K
4800 – 31.2K
4800 – 28.8K
4800 – 31.2K
4800 – 31.2K
2400 – 24.0K
NOTE
3920-A2-GN31-30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere 3921plus

Table of Contents