fan should be located no more than 120 ft from the furthest heater in the zone. Sufficient air
supply must be provided.
Exhauster Capacity:
USA: Natural or mechanical means shall be provided to supply and exhaust at
3
least 4ft
/min/1000Btuh (0.38m
min/1000Btuh (0..43m
terlock to a dedicated exhaust fan. Consult your local code and ANSI Z223.1 latest
edition for all venting requirements and practices.
Canada: It is required that the heater(s) be electrically interlocked to dedicated
exhaust fan(s) by means of an Air Proving Switch. Exhaust fan(s) must be sized to cre-
ate 300 cfm (8.5 cu m/min) exhaust for every 100,000 Btuh (30 kW) or any portion
thereof of total input of installed equipment. Provide combustion and ventilation air
supply compatible with exhaust volume . Consult the latest edition of CSA.B149.1 Sec-
tion 7.22.
15. REMOTE CONTROL OPTION (Single-Stage Models ONLY)
Patio Heaters can be operated using a portable Remote Control Option:
JP-1236-RK Remote Receiver Kit (field installed in the heater)
JP-1236-HS Remote 4-Button Handset Transmitter
The Handset Transmitter is the master component for system setup and operation.
It is recommended to have a backup/spare "twin" handset transmitter in case one is
misplaced
Handsets plug together to "twin" a backup handset with the same codes as master
In the event of any concern for breach of control security (lost handset), master
codes can easily be changed in existing handset(s) on site
Unique random signal codes ensures no interference with any neighboring systems
JP-1236-KT Wireless Keypad Transmitter (wall mounted at patio)
Control up to four heater zones using unique PIN's
Requires a Handset Transmitter as master code controller
Quick Setup instruction sheets accompany the Remote Receiver Kit and the Handset
Transmitter for installation and programming of the system.
Layout and Control:
Each heater requires its own receiver (JP-1236-RK)
Each handset transmitter has 4 channels and can control up to 4 individual heat zones
Multiple receivers can be programmed to one common transmitter channel (button)
Multiple heaters can be simultaneously activated in one heating zone with one
transmitter button
If more than 4 heating zones are required, then more than one master handset transmitter
is required; two master handsets can control up to 8 heating zones,