Download Print this page
Schwank SchwankAir 2045 Installation, Operation And Maintenance Instructions

Schwank SchwankAir 2045 Installation, Operation And Maintenance Instructions

2000 series high efficiency air curtain surface mounted

Advertisement

Quick Links

SchwankAir
For indoor use: openings up to 9 ft-10 in [3m] height
Model and Serial numbers are required when
contacting the manufacturer's service
department.
Proof of purchase is required to make a claim
under warranty.

Advertisement

loading

Summary of Contents for Schwank SchwankAir 2045

  • Page 1 SchwankAir For indoor use: openings up to 9 ft-10 in [3m] height Model and Serial numbers are required when contacting the manufacturer’s service department. Proof of purchase is required to make a claim under warranty.
  • Page 6 Sound pressure levels dB(A) at 3m/10ft distance are for a single air curtain mounted at its maximum mounting height, operating in a room with average acoustic characteristics as defined in CIBSE Guide B5 (reverberation time 0.7s at 1kHz) and a room size equivalent to 8 air changes per hour (ac/h). Care needs to be taken when selecting air curtains for an installation as noise levels can be several dB higher if the mounting height is reduced, if the room is more ‘live’...
  • Page 9 Water flow rates and pressure drops at different water temperatures can be calculated using the SchwankAir coil calculation program. Visit the Schwank website for details.
  • Page 10 See Appendix 1 Page 20 for connection at the unit...
  • Page 11 Feature Explanation Default Notes On restoring power after an electrical interruption all Remote Control settings are retained Fans are switched off when heating level is achieved (AUTO mode only) Air curtain always heats in AUTO mode Enables the room air sensor in the Remote Control...
  • Page 13 To promote increased energy saving a more advanced weather compensation control strategy is available from SchwankAir. Using a heating curve, the discharge air temperature of the airstream coming from the air curtain is controlled against the outside air temperature. Visit the Schwank website for details.
  • Page 14 PCB controller. These include advanced weather compensation control using a heating curve, outlet air temperature control, Modbus BMS control, modulating heater outputs and EEPROMs for non-standard control strategies. Visit the Schwank website for details.
  • Page 15 Manual mode Automatic mode...
  • Page 16 Print Print Name Name Signature Signature Company Company Date Date...
  • Page 18 Weekly maintenance can be carried out by the Cleaner or Janitor from floor level. Before servicing, isolate and disconnect the air curtain from the electrical power.
  • Page 19: Two Year Warranty

    The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to the terms of this document. TWO YEAR WARRANTY Subject to the conditions and limitations stated herein, during the term of this limited warranty, we will supply any component part (at our option a new or repaired component part) of the heater as defined below, which the Manufacturer’s examination determines to be defective in workmanship or material for a period of two (2) years from the date of installation, unless otherwise specified below.