Lighting Instructions; Shut Down Instructions; Heater Finish & Appearance - Schwank InfraSave 2100 Owner's Manual

Patio heater for outdoor application and gas-fired high intensity infrared heater for commercial / industrial non-residential indoor spaces
Hide thumbs Also See for InfraSave 2100:
Table of Contents

Advertisement

alfresco-heating.com

11. LIGHTING INSTRUCTIONS

1. Ensure the correct voltage is supplied, gas supply lines have been properly purged, and gas
valve is switched to the ON position.
2. Turn on power to heater (high or low rate for 2-stage heater), set thermostat (if applicable)
to above ambient temperature, the heater will light.
3. If heater does not light: Turn off power to heater, turn gas valve to OFF position.
4. Wait for five minutes and repeat steps above. If heater does not light after three attempts,
call a qualified service technician.

11.1 SHUT DOWN INSTRUCTIONS

a) For temporary shutdown, turn off the electrical circuit.
b) For complete shutdown, turn off the electrical circuit and turn gas control knob to the
"OFF" position.
12. HEATER FINISH AND APPEARANCE
Stainless Steel Heater: ALL stainless steel heaters will discolor or stain to some extent
due to the impact of heat. This is a normal occurrence and does not effect heater perfor-
mance or the warranty of components.
Paint Finished Heater: Exterior heater surfaces, including any stainless steel compo-
nents, are coated with a black high emissive coating that helps preserve the aesthetic appear-
ance of the heater and improves the radiant heat output.
Handle the heater with care during installation and service to avoid scratching or damaging
the finish.
With extended use, the finish coat will discolor and deteriorate to some extent due to the im-
pact of heat, the deposit of ambient air born particles, and environmental factors.
These are normal occurrences caused by heat, products of combustion, and the environment,
and in no way affect the operation / performance of the heater or the manufacturer's warranty.
OCCASIONAL PAINT FINISH MAINTENANCE:
Wear protective gloves, eyewear, and breathing mask. Ensure that power to the heater is dis-
connected prior to maintenance and the application of any finish coating. Use a fine steel
wool to remove blemishes or unsightly deposit, and smooth the outer surface. The heater fin-
ish coat can be touched up using a high temperature coating such as Thurmalox Stove Paint -
Flat Black-1200°F (650°C) or similar high temperature stove paint that is compatible with the
original finish. No other coating or non-high-temperature paint finish may be applied to the
heater – use of an incompatible finish coating will create a hazardous condition such
as fire or noxious fumes, damage the heater, and void the warranty.
Apply the touch up finish with the heater in its operating orientation (facing down). Ensure that
overspray does not reach or effect the egg crate grilles and the burner tile surface - mask the
heater grilles during any re-finishing. Remove the masking immediately after re-finish and pri-
or to operation of the heater.
22
888-Warm-Glo
2100 / IO 100 Manual
IM110107
RD: SEPT 2016
R.L. 7

Advertisement

Table of Contents
loading

Table of Contents