21. HIGH ALTITUDE INSTALLATION / DERATION
This heater not to be installed at altitude above 6,800 feet.
USA & Canada: The factory installed orifice for this appliance is approved for altitudes zero to 2000
feet above sea level. When installed above 2000 feet, refer to information below.
When this appliance is installed above the standard altitude stipulated the input must be de-rated by 4% for each
1000 ft above sea level. The orifice must be changed according to the chart below - confirm the correct model.
Check with your local utility regarding the gas supply and the de-rating of this appliance.
MODEL
2135 / IO-135 NG
2135 / IO-135 LPG
2150 / IO-150 NG
2150 / IO-150 LPG
2152 / IO-152 NG
1
Per ANSI Z223.1 (NFPA 54)
FOR USE AT ALTITUDES ABOVE (FEET)
Supplied
0
> 2000
38 DMS
41 DMS
JX-0738-DM
JX-0741-DM
50 DMS
52 DMS
JX-0750-DM
JX-0752-DM
31 DMS
32 DMS
JX-0731-DM
JX-0732-DM
46 DMS
48 DMS
JX-0746-DM
JX-0748-DM
31 DMS
32 DMS
JX-0731-DM
JX-0732-DM
1
Gas Orifice Drill Size
/ Part #
USA & CANADA ORIFICE DERATION
> 3000
> 4000
42 DMS
42 DMS
JX-0742-DM
JX-0742-DM
53 DMS
53 DMS
JX-0753-DM
JX-0753-DM
32 DMS
32 DMS
JX-0732-DM
JX-0732-DM
48 DMS
49 DMS
JX-0748-DM
JX-0749-DM
32 DMS
32 DMS
JX-0732-DM
JX-0732-DM
40
888-Warm-Glo
> 5000
> 6000
43 DMS
43 DMS
JX-0743-DM
JX-0743-DM
53 DMS
53 DMS
JX-0753-DM
JX-0753-DM
33 DMS
34 DMS
JX-0733-DM
JX-0734-DM
49 DMS
49 DMS
JX-0749-DM
JX-0749-DM
33 DMS
34 DMS
JX-0733-DM
JX-0734-DM
2100 / IO 100 Manual
RD: SEPT 2016
IM110107
R.L. 7