Schwank InfraSave 2100 Owner's Manual page 10

Patio heater for outdoor application and gas-fired high intensity infrared heater for commercial / industrial non-residential indoor spaces
Hide thumbs Also See for InfraSave 2100:
Table of Contents

Advertisement

alfresco-heating.com
Table 3: INDOOR - MINIMUM MOUNTING & CLEARANCES TO COMBUSTIBLES
Ends
MODEL NO
E
14"
2135 / IO-135 -N\L
14"
2150 / IO150 -N\L
Figure 3: INDOOR - MOUNTING CLEARANCES
NOTE: MOUNT HEATER AT MAXIMUM 30° ANGLE TO AVOID DAMAGE
The clearance to combustible material represents the minimum distance that must be main-
tained between the outer heater surface and a nearby surface. The stated clearance to com-
bustibles represents a surface temperature of 90F° (50C°) above indoor room temperature.
It is the installer's responsibility to ensure that building materials with a low heat tolerance
which may degrade at lower temperatures are protected to prevent degradation. Examples of
low heat tolerance materials include awnings, vinyl siding, fabrics, some plastics, filmy materi-
als, etc.
Note: Do not store or place anything directly under heater
Ensure mounting height in any location is sufficient to prevent patrons from
coming in contact with heater, and clearance to combustibles is maintained.
Table 4: INDOOR - SUGGESTED MOUNTING HEIGHT FOR COMFORT
MOUNTING
PARAMETERS ***
Mounting angle
Suggested height above deck/floor
Under
HORIZONTAL
U
A
S
45"
18"
18"
60"
21"
23"
Horizontal
UP TO MAXIMUM 30° ANGLE
MH
CH
T
108"
138"
20"
120"
153"
25"
MODEL
2135 / IO-135
35,000 Btuh
0
30
9' 6"
9' 0"
10
888-Warm-Glo
B
F
MA
11"
60"
102"
10"
62"
114"
MODEL
2150/2152 / IO-150/152
50,000 Btuh
0
Horizontal
30
10' 6"
10' 0"
2100 / IO 100 Manual
IM110107
RD: SEPT 2016
R.L. 7
CA
132"
147"