Fig 4 - Typical Suspension; Fig 5 - Heater Dimensions & Suspension Angle Options - Schwank P40U Owner's Manual

Low intensity tube type infra red heaters
Table of Contents

Advertisement

FIGURE 4 TYPICAL SUSPENSION
Use all four suspension points + a chain at burner eye hook.
Hardware capable of supporting minimum 100 lbs (45 kg)
at each suspension point.
For seismic and high wind restraint see
Sections 8-A & 8-B.
SERVICE ACCESS: ALLOW A MINIMUM OF
6 INCHES (15 cm) FROM THE ACCESS END
OF THE BURNER AND A MINIMUM OF 24
INCHES (60 cm) FROM EITHER SIDE OF
THE BURNER TO A WALL OR ANY OB-
STRUCTION THAT WOULD RESTRICT OR
LIMIT ACCESS TO THE BURNER (SEE
SECTIONS 5 & 6 - PRE-INSTALLATION
SURVEY AND MOUNTING CLEARANCES)
For 30° angle mount: Remove burner (4 bolts + spark wire); Install the tube system; Reinstall
burner to flange using appropriate holes to maintain horizontal orientation of burner.
FIGURE 5 HEATER DIMENSIONS & SUSPENSION ANGLE OPTIONS
Turbulators (factory installed): Burner side tube: 36" (914 mm)
P40U-F / P40U-IF I&O Manual
IM101220
RD: MAR 2014
RL: 4B
Vent side tube: 90" (2286 mm)
Vent side
always upper
Burner always
horizontal
14
Connect to properly
grounded 120V
power supply
.