4.2 Remote Operation

4.2.1 Remote Programming (Touch-Tone Phone)

The Access Plus unit can be programmed and operated from a touch-tone telephone. Be sure that the ability for the unit to
answer an incoming call has not been disabled (section 2.4.9).
Note: The master code cannot be programmed remotely, it can only be programmed from the system keypad (section 2.1).
1. Call the unit's phone number. After the programmed number of rings (2.4.9) the unit will answer with a tone.
2. Follow the desired programming steps in Section 2 of this manual.
3. When complete with the desired programming function, hang up. You cannot use 0# pressed together to end
programming steps from a touch-tone telephone. Wait 30 seconds before calling back to program another feature.

4.2.2 Remote Relay Activation (Touch-Tone Phone)

The Access Plus system relays can be activated from a Touch-Tone phone. Be sure that the ability for the Access Plus unit
to answer an incoming call has not been disabled (section 2.4.9). Refer to the tone open numbers that where programmed
in section 2.4.8 to determine each of the activation numbers.
Momentary Activation (Relay activates for its programmed relay strike time, section 2.4.7).
Hold Open (Relay will activate and remain activated).
Deactivate (Relay will deactivate).
Hold 1 Hour (Relay will activate for 1 hour and then automatically deactivate).
To activate the relay(s) from a touch-tone phone, perform the following steps:
1. Call the unit's phone number. After the programmed number of rings (2.4.9) the unit will answer with a tone.
2. Press
1 6 and enter the MASTER CODE. [
*
(Two-way voice communication is also enabled at this point)
3. Enter the desired tone open number (2.4.8). [ _ (beep)]
4. Hang up.

4.2.4 Remote Relay Activation Check (Touch-Tone Phone)

The Access Plus unit can be called to check if relay 1, relay 2, or both relays on the unit's main circuit board are latched
and holding a door or gate in the open (unlocked) position. Relays 3 - 8 (RS-485 devices) cannot be checked from the
phone.
1. Call the unit's phone number. After the programmed number of rings (2.4.9) the unit will answer with a tone.
2. Press
1 6 and enter the MASTER CODE. [
*
(Two-way voice communication is also enabled at this point)
3. press
7. [
*
4. Listen for the following sequence of tones.
No Tones: neither relay is activated.
Relay 1 Activated: beep - pause - beep - pause . . .
Relay 2 Activated: beep beep - pause - beep beep - pause . . .
Both Relays Activated: beep beep beep - pause - beep beep beep - pause . . .
5. Hang up.