Sub-Net Mask (Reboot Required); Set The Gateway (Router) Ip Address (Reboot Required); Set The Port Number (Reboot Required) - Intertek 1802 Installation & Owner's Manual

Pc programmable telephone entry/access control system
Table of Contents

Advertisement

2.3.3 Sub-Net Mask
Factory setting is: 255.255.255.000
All sub-net mask should be set to 255.255.255.000. This rarely needs to be changed, consult with your network expert
first. Valid values for any of the three digit numbers is 000 to 255.
1. Press
2. Enter the sub-net mask number. Use the
1 1
2 2
3 3
CODE
Adams J
1
Bernard E
9
4 4
5 5
6 6
Brown L
5
Davis T
2
7 7
8 8
9 9
Hodges S
4
Miller J
6
Smith K
8
0 0
Thomas W
3
Zimmer R
7
System Keypad
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
2.3.4 Set the Gateway (Router) IP Address
Factory setting is: 192.168.001.001
If the unit is connected directly to the computer with a crossover cable, then this address must be set to 000.000.000.000.
If the unit is connected to the computer through a router, then set this value to the router's IP address. Valid value for any
of the three digit numbers is 000 to 255. (See section 1.11.2 for network configurations and addresses)
1. Press
2. Enter the gateway (router) IP address. Use the
1 1
2 2
3 3
CODE
Adams J
1
Bernard E
9
4 4
5 5
6 6
Brown L
5
Davis T
2
Hodges S
4
7 7
8 8
9 9
Miller J
6
Smith K
8
0 0
Thomas W
3
Zimmer R
7
System Keypad
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
2.3.5 Set the Port Number
Factory setting is: 01030
This must be the same port number that was programmed in the software. Valid values are 01024 to 65535.
All 5 digits must be entered in the field, for example: 1030 must be entered as 01030
1. Press
2. Enter the port number, then press
1 1
2 2
3 3
CODE
Adams J
1
Bernard E
9
4 4
5 5
6 6
Brown L
5
Davis T
2
Hodges S
4
7 7
8 8
9 9
Miller J
6
Smith K
8
Thomas W
3
0 0
Zimmer R
7
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
System Keypad
If you are OR are going to use a computer with the Access Plus system, NO other programming at the System
Keypad is required. All programming parameters beyond this point can be set in the Management software.
This software will show all the specific programming parameters that will exist in the memory of the Access Plus system
after it has been programmed. It can be easily recalled for future modification or re-programming.
1 1
2 2
3 3
NAME
CODE
Adams J
1
Bernard E
9
4 4
5 5
6 6
Brown L
5
Davis T
2
Hodges S
4
7 7
8 8
9 9
Miller J
6
Smith K
8
0 0
Thomas W
3
Zimmer R
7
System Keypad
34
(reboot required)
5 2 and enter the MASTER CODE. [
*
[ _ _ _
(beep) _ _ _
(beep) _ _ _
*
*
5 3 and enter the MASTER CODE. [
*
[ _ _ _
(beep) _ _ _
(beep) _ _ _
*
*
(reboot required)
5 6 and enter the MASTER CODE. [
*
PC's only, NOT for use with MACs
The system keypad DOES NOT have the capability to show any of the programming that will exist
in the memory of the unit after being programmed. The only way to keep track of the specific
parameters that have been programmed into the unit for future reference when NOT using the
management software, is to physically write down all the information in a log (In back of manual).
5 2 _ _ _ _ (beep)]
*
key to enter the "dot".
*
(beep) _ _ _
(beep)]
*
*
(reboot required)
5 3 _ _ _ _ (beep)]
*
key to enter the "dot".
*
(beep) _ _ _
(beep)]
*
*
5 6 _ _ _ _ (beep)]
*
. [ _ _ _ _ _
(beep)]
*
*
STOP!
1810-162-A-6-16

Advertisement

Table of Contents
loading

Related Products for Intertek 1802

This manual is also suitable for:

1810 flush18081810 surface

Table of Contents