Rs-485 Configurations, Sample Of Multiple Unit Configuration Connection (Auto-Dialer Only) - Intertek 1802 Installation & Owner's Manual

Pc programmable telephone entry/access control system
Table of Contents

Advertisement

Auto-Dialer ONLY -
Phone
Company
OR
Internet
1st Unit
Unique Master Code
Relay 2
Relay 1
2nd Unit
Unique Master Code
Relay 2
Each unit has 2
Relay 1
internal relays
to control TWO
(2) access
control devices
3rd 1Unit
like a vehicular
Unique Master Code
gate operator
and a
pedestrian gate
or door:
Relay 2
Address 001
Relay 1
and 002.
4th Unit
Unique Master Code
Relay 2
Relay 1
5th Unit
Unique Master Code
Relay 2
Relay 1
Units MUST be programmed for MULTIPLE UNITS, see section 2.4.2.
1810-162-A-6-16
Sample of Multiple Units Configuration Connection
Maximum of 5 Units
Phone In
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
0 0
OPERATING
INSTRUCTIONS
1.
Locate Code Number on
Directory.
2.
Press Code Number.
If Line is Busy, Press Any
Button to Hang Up.
Try Again.
3.
Enter on Tone.
Phone Out
Phone In
RS-485 Devices (Relays 3 - 8) connected to 2nd unit if desired (2nd unit's SW2 term. switch is ON).
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
0 0
OPERATING
INSTRUCTIONS
1.
Locate Code Number on
Directory.
2.
Press Code Number.
If Line is Busy, Press Any
Button to Hang Up.
Try Again.
3.
Enter on Tone.
Phone Out
Phone In
RS-485 Devices (Relays 3 - 8) connected to 3rd unit if desired (3rd unit's SW2 term. switch is ON).
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
0 0
OPERATING
INSTRUCTIONS
1.
Locate Code Number on
Directory.
2.
Press Code Number.
If Line is Busy, Press Any
Button to Hang Up.
Try Again.
3.
Enter on Tone.
Phone Out
Phone In
RS-485 Devices (Relays 3 - 8) connected to 4th unit if desired (4th unit's SW2 term. switch is ON).
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
0 0
OPERATING
INSTRUCTIONS
1.
Locate Code Number on
Directory.
2.
Press Code Number.
If Line is Busy, Press Any
Button to Hang Up.
Try Again.
3.
Enter on Tone.
Phone Out
Phone In
RS-485 Devices (Relays 3 - 8) connected to 5th unit if desired (5th unit's SW2 term. switch is ON).
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
0 0
OPERATING
INSTRUCTIONS
1.
Locate Code Number on
Directory.
2.
Press Code Number.
If Line is Busy, Press Any
Button to Hang Up.
Try Again.
3.
Enter on Tone.
Maximum of 6 RS-485 Devices "Daisy Chain" per Unit
Relay 3
Relay 4
Relay 5
Term Sw
Term Sw
Term Sw
Address
Address
Address
003
004
005
OFF
OFF
OFF
Note: Any Keypad, Cardreader or RF Receiver daisy chain sequence allowed. Each
RS-485 device will control 1 "Normally Open" OR "Normally Close" access control
device. ALL RS-485 devices must be powered from their own power source.
Relay 6
Relay 7
Relay 8
Term Sw
Term Sw
Term Sw
Address
Address
Address
006
007
008
OFF
OFF
ON
Terminated
End Device
ON
SW2
ON
SW2
ON
SW2
ON
SW2
27

Advertisement

Table of Contents
loading

Related Products for Intertek 1802

This manual is also suitable for:

1810 flush18081810 surface

Table of Contents