Additional Off-Line Relay Function; Time Zone Restricted" Access Code Programming; Delete An Access Code (Simple And Time Zone Restricted); Delete All Access Codes For The Same Type Of Device (Simple And Time Zone Restricted) - Intertek 1802 Installation & Owner's Manual

Pc programmable telephone entry/access control system
Table of Contents

Advertisement

2.6.3 Additional Relay Off-Line Function

Factory setting is 0 (No Devices Connected).
This programming sequence sets how the remote RS-485 devices connected to the Access Plus unit will respond if the
RS-485 communication link fails to a specific remote device.
Entering a 1 in step 2 sets the remote device to GRANT ACCESS to any five-digit card, transmitter or access code, whether
it has been programmed into the system or not at the specific device location where the RS-485 communication link failed.
Entering a 0 in step 2 sets the remote device to NOT GRANT ACCESS at the specific device location where the RS-485
communication link failed. In this case, the Access Plus unit and any other remote RS-485 devices may still be operating
normally as along as they have a good RS-485 communication link.
1. Press
2. Enter 0 OR 1, then press
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.6.4 "Time Zone Restricted" Device Access Code Programming

This programming sequence programs access codes into the system memory with time zone restrictions applied. It also
allows programming of the access codes to momentarily activate a relay or to hold open (latch) a relay.
Note: Up to 50 access codes can be programmed into the system. This 50 includes "simple" access codes programmed in
2.6.1 AND "time zone restricted" access codes programmed in 2.6.4. For example, if 10 "simple" access codes are
programmed in 2.6.1, then only 40 "time zone restricted" access codes can be programmed in 2.6.4.
1. Press
2. Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
3. Choose and enter a five-digit access code, then press
4. Enter a minimum of 1, and a maximum of 4 time zones (valid time zones are 0 through 6) that you
5. Enter 0
6. Repeat steps 2 through 5 to program additional access codes (Time zone restricted).
7. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.6.5 Delete an Access Code (Simple and Time Zone Restricted)

This programming sequence deletes individual "simple" and "time zone restricted" access codes that have been
programmed into the system.
1. Press
2. Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
3. Enter the five-digit device access code to be deleted, then press
4. Repeat steps 2 and 3 to delete additional existing "simple" and "time zone restricted" access codes.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
2.6.6 Delete All Access Codes for the Same Type of Device (Simple and TZR)
This programming sequence deletes ALL existing "simple" and "time zone restricted (TZR)" access codes for the same
type of device. To delete ALL existing "simple" and "time zone restricted" access codes, this programming sequence will
need to be preformed for each type of device that is connected to the system.
WARNING: Once started, all "simple" and "time zone restricted" access codes for the same type of device will be erased.
1. Press
2. Enter the device type (0 = card, 1 = transmitter, 2 = keypad, 3 = other), then press
3. Press 9 9 9 9, then press
4. The programming sequence will end itself automatically. [beeeeeep]
42
0 7 and enter the MASTER CODE. [
*
*
7 0 and enter the MASTER CODE. [
*
want to apply to this access code, then press
Time zone 0 - Always deny access.
Time zone 1 - Allows 24/7 access for relay 1 and any additional relays.
Time zone 2 - Allows 24/7 access for relay 2 and any additional relays.
Time zones 3, 4, 5 and 6 - Are time zones that have been programmed in 2.7.6.
for momentary relay activation or enter 1
*
7 1 and enter the MASTER CODE. [
*
See 2.6.1 and/or 2.6.4 for the five-digit access code.
7 2 and enter the MASTER CODE. [
*
*
0 7 _ _ _ _ (beep)]
*
. [ _
(beep)]
*
7 0 _ _ _ _ (beep)]
*
. [ _ _ _ _
*
*
7 1 _ _ _ _ (beep)]
*
7 2 _ _ _ _ (beep)]
*
. [ 9 9 9 9 (beep)]
. [ _ _ _ _ _
(beep)]
*
*
(beep)]
*
to hold open (latch) the relay. [ _
. [ _ _ _ _ _
(beep)]
*
*
. [ _
(beep)]
*
*
(beep)]
*
. [ _
(beep)]
*
*
. [ _
(beep)]
*
*