2.4.6 Talk Time

Factory setting is 060 (60 Seconds).
This programming sequence sets the maximum time allowed for conversation when the Access Plus unit places a call
either through the 1816 Access Plus telephone interface (directory codes 01-23) or through the auto-dialer (directory
codes 24-50). Talk time can be set from 10 seconds up to 255 seconds (4 minutes, 15 seconds) and is entered as a
three-digit number. For example, to set a talk time of 30 seconds, enter 030 in step 2.
1. Press
2. Enter the three-digit talk time code (010-255), then press
3. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.4.7 Relay Strike Time

Factory setting for Relays 1 and 2 is 01 (1 Second). Relays 3 through 8 are not set.
These steps will program the system relay strike times.
Strike times can be programmed from 1/4 second - enter 0 0 * in step 3, up to 99 seconds - enter 9 9 * in step 3.
System relays 1 and 2 are the two relays on the Access Plus unit's main circuit board. System relays 3 through 8 are the
relays associated with additional RS-485 devices (card readers, keypads, RF receivers, etc.) connected to the system.
1. Press
2. Enter a relay number (1 – 8), then press
3. Enter the two-digit strike time (00-99), then press
4. Repeat steps 2 and 3 to set other relay strike times if necessary.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]

2.4.8 Tone Open Numbers

Factory setting is 9876 for Relay 1; 5432 for Relay 2. Relays 3 – 8 are not set.
These steps will program the tone open number(s) for each relay in the system (each relay is programmed independently).
You will need to enter a four-digit number (see chart below) to set each relay in step 3. If a function is not desired, enter #
in place of a number. Use a different number for each of the four-digits in step 3 when multiple functions are desired.
Example 1: If you want the relay to have a momentary activation function only, and you want the relay to activate when the
number 9 is pressed, enter 9 # # #
Example 2: If you only want the relay to hold open when the number 8 is pressed and the relay deactivated when the
number 7 is pressed, enter # 8 7 #
1. Press
2. Enter a relay number (1 – 8), then press
3. Choose and enter a four-digit tone open number code (see chart below), then press
4. Repeat steps 2 and 3 to set other relay tone open number(s) if desired.
5. Press 0 # TOGETHER to end. [0 # (beeeeeep)]
4 Digit Tone Open Number Code
1st Digit (Step 3)
2nd Digit (Step 3)
3rd Digit (Step 3)
4th Digit (Step 3)
38
0 8 and enter the MASTER CODE. [
*
0 3 and enter the MASTER CODE. [
*
in step 3.
*
in step 3.
*
0 5 and enter the MASTER CODE. [
*
[ _ _ _ _
(beep)]
*
If a tone open function is not desired, enter # in place of a number.
Momentary activation. The relay will activate for its programmed relay strike time.
Hold open. The relay will activate and remain activated until commanded to deactivate.
Deactivate relay.
Hold open 1 hour. The relay will activate for 1 hour and then deactivate itself.
0 8 _ _ _ _ (beep)]
*
. [ _ _ _
*
0 3 _ _ _ _ (beep)]
*
. [ _
(beep)]
*
*
. [ _ _
(beep)]
*
*
0 5 _ _ _ _ (beep)]
*
. [ _
(beep)]
*
*
Function
(beep)]
*
.
*
1810-162-A-6-16

Advertisement

Table of Contents
loading

Related Products for Intertek 1802

This manual is also suitable for:

1810 flush18081810 surface

Table of Contents