Main Terminal Description; Access Plus System Interface Board; Rs-485 8-Pin Connector Description - Intertek 1802 Installation & Owner's Manual

Pc programmable telephone entry/access control system
Table of Contents

Advertisement

1.10 Main Terminal Description

Phone In
(Twisted Pair)
1. Phone In (Negative - Ring)
OR
Wireless
2. Phone In (Positive - Tip)
Adapter
3. Ground (Required)
4. Phone Out (Positive - Tip)
Phone Out
(Twisted Pair)
5. Phone Out (Negative - Ring)
6. Not Used.
Emergency
7. Switch Input Relay 1. A switch closure across terminals 7 & 9
and/or Postal
will activate relay 1 for its programmed strike time.
Entry Switch
8. Switch Input Relay 2. A switch closure across terminals 8 & 9
will activate relay 2 for its programmed strike time.
Back-Up
9. - 12 VDC Battery Negative. Also Common for terminals 7 & 8.
Battery Power
10. + 12 VDC Battery Positive.
11. Relay 1 Normally Open
Relay 1
12. Relay 1 Normally Closed
(Access Control Device)
13. Relay 1 Common
14. Relay 2 Normally Open
Relay 2
15. Relay 2 Normally Closed
(Access Control Device)
16. Relay 2 Common
Input Power
17. 16.5 VAC Input Power
(Transformer)
18. 16.5 VAC Input Power
DO NOT
use 24V.

1.11 Access Plus System Interface Board

The Access Plus interface board (1972-010) is piggybacked onto the main unit's Plus circuit board (1970-010). The interface
board provides additional connections to the unit for keypads, card readers and/or RF receivers using RS-485 communication
protocol.
The Access Plus system can be programmed via a PC using a network or modem connection. An RJ-45 jack (Cat5) is provided
on the interface board for network connections.

1.11.1 RS-485 8-Pin Connector Description

Use the RS-485 terminals to add up to six (6) card readers, keypads and/or RF receivers to the Access Plus system. These
devices must be wired in a daisy-chain format with a maximum wire run distance of 4000 feet. We recommend that you use
Cat5e wire for all RS-485 wire runs.
DO NOT power RS-485 devices from the Access Plus system. These devices must be supplied with their own power source.
Refer to the individual device wiring instructions for connection information and wiring guidelines for these products.
1970-010
J1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
24
WARNING
input voltage to terminals
9 and 10 is 14.5 Volts DC.
BATT CHARGE LED: When
battery is connected to 9
and 10, Green LED will
light when charging and
turn OFF when charged.
J4
RS-485 DATA A (+)
1
RS-485 DATA B (-)
2
RS-485 Common
3
4
Terminals 4-8 are
ONLY used with
5
1816 Access Plus
6
Telephone
Interface
7
application.
8
See section 1.9.
1970-010
J1
1
2
3
4
5
6
7
8
9
10
11
12
13
Maximum
14
15
16
17
18
RS-485 RX
TERMINATION
LAN DOWN
BAD DNS
SW2
DATA TRANSMIT
LAN CONNECTION
J1
RJ-45
Jack
(Cat5)
KEYPAD
BATT
CHARGE
OV
Over Voltage Power Note:
OV LED will light up if too much
power is applied to circuit board.
MODEM / TCP ENB
SW1
PHONE LINE
IN USE
1972-010
J3
J4
1
2
3
4
5
6
7
8
M M
MASTER
CODE
MIC VOL
1810-162-A-6-16