Performing A Self-Test - Avaya H.323 9608 Installing And Maintaining

Hide thumbs Also See for H.323 9608:
Table of Contents

Advertisement

Use the following procedure to set the Site-Specific Option Number (SSON).
Procedure
1. Select SSON from the Craft Procedures screen. The deskphone displays the
2. To change the setting, use the dialpad to enter a valid SSON value between 128
3. Press Save to store the new setting and redisplay the Craft Procedures screen.

Performing a self-test

About this task
Note:
9600 series IP deskphones store two software code images in reprogrammable non-volatile
memory. The primary image, called the "big app" must be running to perform a self-test. The
backup image, called the "little app" does not support the self-test.
Note:
When updating local Craft procedures from a touch screen deskphone, touching the line
you want to change or the applicable softkey produces the same result as selecting a line
and pressing the applicable softkey on a non-touch screen IP deskphone.
Use the following procedure to perform self-testing:
Procedure
1. Select TEST from the Craft Procedures Screen. The deskphone displays the
2. Press Cancel to return to the Craft Procedures screen without testing the
Installing and Maintaining Avaya IP Deskphone H.323 9608, 9611G, 9621G, and 9641G
following text:
Current setting:
New Setting:
where the setting is the current system value of NVSSON.
and 255.
following text:
Press Test to confirm.
deskphone.
Press Test to start deskphone testing.
The test performs the following actions:
Performing a self-test
August 2013
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

H.323 9621gH.323 9641gH.323 9611g

Table of Contents