Generator, 4 Lead; Generator, 12 Lead - Kohler 6EKOD Service Manual

Marine generator sets
Hide thumbs Also See for 6EKOD:
Table of Contents

Advertisement

1.3 Generator, 4 Lead

Component Specification
Main field (rotor) resistance (cold)—ohms @ 20_C (68_F)
Stator output voltages with separately excited generator, using 12-volt battery (60 Hz only)
1--2, 3--4—volts
55--66—volts
Cold stator resistance
1--2, 3--4—ohms
55--66—ohms
Component Specification
Hot exciter field voltage/amperage readings at rated voltage
No load (63 Hz)—volts/amps
Full load (60 Hz)—volts/amps
Exciter field resistance (cold)—ohms @ 20_C (68_F)
Exciter armature resistance (cold)—ohms (line-to-line)
Main field (rotor) resistance (cold)—ohms @ 20_C (68_F)
Stator output voltages with separately excited generator, using 12-volt battery (60 Hz only)
1--2, 3--4—volts
55--66—volts
Cold stator resistance
1--2, 3--4—ohms
55--66—ohms

1.4 Generator, 12 Lead

Component Specification
Hot exciter field voltage/amperage readings at rated voltage
No load (63 Hz)—volts/amps
Full load (60 Hz)—volts/amps
Exciter field resistance (cold)—ohms @ 20_C (68_F)
Exciter armature resistance (cold)—ohms (line-to-line)
Main field (rotor) resistance (cold)—ohms @ 20_C (68_F)
Stator output voltages with separately excited generator, using 12-volt battery (60 Hz only)
1--4, 2--5, 3--6, 7--10, 8--11, 9--12—volts
55--66—volts
Cold stator resistance
1--4, 2--5, 3--6, 7--10, 8--11, 9--12—ohms
55--66—ohms
TP-6774 2/14a
6EKOD
5EFKOD
4.4--5.0
130
155
0.19
2.7
9EKOZD/
11EKOZD/
7EFKOZD
9EFKOZD
12/0.8
5/0.9
33/2.2
14/2.3
4.8
4.8
1.18
1.18
5.7
5.7
115
184
155
193
0.19
0.28
1.9
1.3
11EKOZD/
9EFKOZD
7/1.3
20/3.3
4.8
1.18
5.7
160
192
0.34
0.88
Section 1 Specifications
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9-11ekozd5efkod7-9efkozd

Table of Contents